Description

!

5/5 - (1 vote)

Additional information

watt

750W ~ 4000W

1 review for Growatt SPH 3000TL BL-UP

  1. Liam H

    I bought Growatt SPH 3000TL from your website tnx for good pricing

Add a review

Your email address will not be published. Required fields are marked *

Input Data (PV)

Max. recommended PV power
(for module STC)
6500W
Max. DC voltage 550V
Start voltage 120V
MPP voltage range 120V-550V/370V
No. of MPP trackers 2
No. of PV strings per MPP tracker 1
Max. input current per MPP tracker 13.5A
Max. short-circuit current per MPP tracker 16.9A

Output Data (AC)

AC nominal power 3000W
Rated AC apparent power 3000VA
Nominal AC voltage (range*) 230V/ (180Vac~260Vac)
AC grid frequency(range*) 50/60 Hz (45-55Hz/55-65 Hz)
Rated output current 13.5A
Adjustable power factor 0.8leading…0.8lagging
THDi <3%
AC grid connection type Single phase

Battery Data (DC)

Battery voltage range 42~59V
Max charging and discharging current 66A
Continuous charging and discharging power 3000W
Type of battery lithium/lead-acid 

Backup Power (AC)

Max. AC output power 3000W
Rated output current 13A
Nominal AC output voltage 230Vac
Nominal AC output frequency 50/60HZ
THDv <3%
Switch time <10ms

Efficiency

>

MAX. efficiency 97.2%
European efficiency 97%
MPPT efficiency 99.9%

Protection devices

DC switch Yes
DC reverse polarity protection Yes
AC/DC surge protection Type II
AC short-circuit protection Yes
Ground fault monitoring Yes
Grid monitoring Yes
Anti-islanding protection Yes
Residual-current monitoring unit Yes
Insulation resistance monitoring Yes

General data

Dimensions (W / H / D) 565/453/188mm
Weight 27kg
Operating temperature range –25 °C ... +60 °C
Nighttime power consumption <13W
Topology Transformerless
Cooling Natural
Protection degree IP65
Relative humidity 0~100%
Altitude 2000m
DC connection H4 / MC4 (Optional )
AC connection Connector
Display LCD+LED
Interfaces: RS485/CAN/USB Yes
Monitor : RF/WIFI/GPRS Optional
Warranty: 5 years / 10 years

 

 

Yes / Optional
CE, IEC62109, IEC 62040, VDE-AR-N 4105, VDE 0126, UTE C 15-712, C10/C11,EN50549, CEI 0-21, CEI 0-16, IEC62116, IEC61727, AS/NZS 4777 , G98, TOR Erzeuger
 

* The AC Voltage Range may vary depending on specific country grid standard.